Supermicro Ultra SuperServer SYS-220U-TNR
Key Applications |
Virtualization |
HPC |
Cloud Computing |
High End Enterprise Server |
Software Defined Storage |
Application Tier Service Provider |
5G/Telco |
Key Features |
Dual Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable Processors |
Intel® C621A Chipset |
32 DIMM Slots; |
Up to 8TB DRAM; |
Up to 8TB Intel® Optane™ Persistent Memory (up to 12TB with DRAM); |
3200/2933/2666 ECC DDR4 LRDIMM;RDIMM; |
Product SKUs | |
SuperServer SYS-220U-TNR (Black Front & Silver Body) | |
Motherboard | |
Super X12DPU-6 | |
Processor | |
CPU | Dual Socket P+ (LGA-4189) |
3rd Gen Intel® Xeon® Scalable processors | |
Support CPU TDP 270W * | |
Cores | Up to 40C/80T; Up to 60MB Cache |
Note | *Certain CPUs with high TDP may be supported only under specific conditions. Please contact Supermicro Technical Support for additional information about specialized system optimization |
System Memory | |
Memory | Memory Capacity: 32 DIMM slots |
Up to 8TB: 32x 256 GB DRAM | |
Up to 12TB: 16x 512 GB PMem and 16x 256 GB DRAM | |
Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM;LRDIMM | |
Intel® Optane™ persistent memory 200 series | |
Memory Voltage | 1.2 V |
Error Detection | ECC |
On-Board Devices | |
SATA | SATA3 (6Gbps) via Intel® PCH 621A; RAID 0/1/5/10 support |
NVMe | NVMe (16GT/s); RAID 0/1/5/10 support |
NVMe (16GT/s); RAID 0/1/5/10 support | |
Chipset | Intel® C621A |
Network Connectivity | 2x 10GbE BaseT with Intel® X710-AT2 (optional) OR |
2x 10GbE BaseT and 2x 10GbE SFP+ with Intel® X710-TM4 (optional) | |
No NIC option supported | |
IPMI | Support for Intelligent Platform Management Interface v.2.0 |
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support | |
Input / Output | |
LAN | 1 RJ45 Dedicated BMC LAN port |
USB | 2 USB 3.0 port(s) (2 rear) |
Video | 1 VGA port(s) |
Serial Port | 1 COM Port(s) (1 rear) |
DOM | 2 SuperDOM (Disk on Module) port |
System BIOS | |
BIOS Type | AMI 32MB SPI Flash EEPROM |
Management | |
Software | Supermicro Out of Band (OOB) License (Included with Server) |
Redfish API | |
IPMI 2.0 | |
Intel® Node Manager | |
KVM with dedicated LAN | |
SUM | |
NMI | |
Watch Dog | |
SuperDoctor® 5 | |
Power Configurations | ACPI Power Management |
Power-on mode for AC power recovery | |
PC Health Monitoring | |
CPU | 7 +1 Phase-switching voltage regulator |
Monitors for CPU Cores, Chipset Voltages, Memory | |
FAN | Fans with tachometer monitoring |
Pulse Width Modulated (PWM) fan connectors | |
Status monitor for speed control | |
Temperature | Monitoring for CPU and chassis environment |
Thermal Control for fan connectors | |
Chassis | |
Form Factor | 2U Rackmount |
Model | CSE-219U3TS-R1K62P-T |
Dimensions and Weight | |
Height | 3.5″ (89mm) |
Width | 17.2″ (437mm) |
Depth | 28.2″ (717.2mm) |
Package | 9.96″ (H) x 24.6″ (W) x 45.43″ (D) |
Weight | Net Weight: 37 lbs (16.8 kg) |
Gross Weight: 63 lbs (28.6 kg) | |
Available Color | Black Front & Silver Body |
Front Panel | |
Buttons | Power On/Off |
UID button | |
LEDs | HDD activity |
LAN1 activity | |
LAN2 acticity | |
Power Fail | |
Power status | |
System information (overheat/UID) | |
Expansion Slots | |
PCI-Express (PCIe) | 1 PCIe 4.0 x16 FH, 10.5″L slot(s) |
5 PCIe 4.0 x8 FH, 10.5″L slot(s) | |
1 PCIe 4.0 x8 Internal LP slot(s) | |
1 PCIe 4.0 x16 LP slot(s) | |
Note | Optional RSC-W2-66G4 enables PCIe x16 in slots 5, 7. Slots 6,8 will be disabled. |
Drive Bays / Storage | |
Hot-swap | 24x 2.5″ hot-swap NVMe/SATA/SAS drive bays (22x 2.5″ NVMe hybrid) (SAS/NVMe support requires additional parts. Please see the Optional Parts list.) |
System Cooling | |
Fans | 4x 8cm heavy duty fans with optimal fan speed control |
Air Shroud | 2 Air Shroud(s) |
Power Supply | |
1U 1600W Redundant Titanium AC Power Supply with PMbus 73.5x203x40mm | |
Dimension | 73.5 x 40 x 203 mm |
(W x H x L) | |
AC Input | 1000W: 100-127Vac / 50-60Hz |
1600W: 200-240Vac / 50-60Hz | |
+12V | Max: 83A / Min: 0A (100Vac-127Vac) |
Max: 133A / Min: 0A (200Vac-240Vac) | |
12V SB | Max: 2.1A / Min: 0A |
Output Type | Gold Finger Connector |
Certification | Titanium Level |
[ Test Report ] | |
Operating Environment | |
Environmental Spec. | Operating Temperature: |
10°C ~ 35°C (50°F ~ 95°F) | |
Non-operating Temperature: | |
-40°C to 60°C (-40°F to 140°F) | |
Operating Relative Humidity: | |
8% to 90% (non-condensing) | |
Non-operating Relative Humidity: | |
5% to 95% (non-condensing) |
Specification
Standard Parts (Parts Included) | |||
Part Number | Qty | Description | |
Motherboard / Chassis | MBD-X12DPU-6 | 1 | Super X12DPU-6 Motherboard |
CSE-219U3TS-R1K62P-T | 1 | 2U Chassis | |
Backplane | BPN-NVME4-216N-S24 | 1 | 2U 24-slot all-hybrid direct-attached backplane, support 24x 2.5 |
Cable | CBL-CDAT-0674 | 2 | 4 Pin to 4 Pin I2C Cable, 30cm, 26AWG, 4 Wires, Pinout 1-1 |
CBL-PWEX-0924 | 1 | 2×4,P3.0 to 2×4,P4.2,YL/RED,9.5A,24cm,16AWG,RoHS | |
CBL-PWEX-0925 | 2 | 2×4,P3.0 to 2×4,P4.2,YL/RED,9.5A,55cm,16AWG,RoHS | |
CBL-SAST-1250F-100 | 2 | Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,50CM,100 | |
CBL-SAST-1270F-100 | 1 | Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,70CM,100 | |
CBL-0088L | 4 | 10.5″ 4PIN FAN POWER CORD FOR 743X-645,PBF | |
CBL-0160L | 2 | US POWER CORD 16AWG, PB FREE | |
Riser Card | RSC-W2-8888G4 | 1 | 2U LHS WIO Riser card with four PCIe 4.0 x8 slots,HF,RoHS |
RSC-WR-6 | 1 | 1U RHS WIO Riser card with one PCIe 4.0 x16 slot,HF,RoHS | |
Software | SFT-OOB-LIC | 1 | License key for enabling OOB BIOS management |
Heatsink / Retention | SNK-P0078P | 2 | 2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-1K62A-1R | 2 | AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 – 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH |
*Drive Tray(s) | MCP-220-00047-0B | 24 | Black gen 3rd hot-swap 2.5inch HDD tray |
*Rail Set | MCP-290-00057-0N | 1 | Rail set, quick/quick, default for 4U 17.2″ W |
MCP-290-00060-0N | 1 | Threaded rail adapter default for round hole rack | |
MCP-290-00115-0N | 1 | Inner rail, quick-release type | |
MCP-290-00117-0N | 1 | Outer rail, quick-release type | |
*Air Shroud | MCP-310-81905-0B | 1 | Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH |
*Fan | FAN-0209L4 OR | 4 | 80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above |
FAN-0206L4 | 80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers | ||
Notes: | |||
Parts with * are inside the chassis | |||
Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables…..etc. | |||
Optional Parts List | |||
Part Number | Qty | Description | |
2 Rear 2.5″ Hot-swap SATA Drive Bays (Complete System Only) | MCP-240-82922-0N-OEM • | 1 | Rear 2x 2.5″ HDDs riser bracket kit for SC829U/219U, tool-less |
2U Cable Management Arm | MCP-290-00128-0N & | 1 | 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42″ in depth) |
MCP-290-00127-0N | |||
2U Front Bezel | MCP-210-82601-0B • | 1 | Black Front Bezel Suitable for 829U and 219U chassis with standard thumbscrew handle. |
Add-on card for M.2 support | AOC-SLG3-2H8M2-O | – | 2x Hybrid NVMe/SATA M.2 RAID Carrier, Standard LP,RoHS |
CacheVaults | BTR-CVPM05 + BKT-BBU-BRACKET-05 | – | CacheVault for Broadcom 3908/3916 with Supercap |
BTR-CV3108-U1 | – | CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra | |
Drive Tray | MCP-220-00167-0B • | 1 ~ 22 | 2.5 drive tray, Orange tab (for hotswap NVMe drive) |
Global Services & Support | OSNBD3/2/1 | – | 3/2/1-year onsite NBD service |
OS4HR3/2/1 | – | 3/2/1-year onsite 24x7x4 service | |
Intel® VROC RAID Key Options | AOC-VROCINTMOD | 1 | Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) |
AOC-VROCPREMOD • | 1 | Intel VROC Premium, RAID 0, 1, 5, 10 | |
AOC-VROCSTNMOD | 1 | Intel VROC Standard, RAID 0, 1, 10 | |
Network Card(s) | AOC Compatibility Matrix | – | Standard Networking AOC Matrix |
NVMe Support Kit | CBL-KIT-220U-TNR-22N + 3 AOC-SLG4-4E4T-O | 1 | 22 NVMe Support Kit for X12 Ultra 220U-TNR without NIC UIO |
CBL-KIT-220U-TNR-22 + 2 AOC-SLG4-2E4T-O + 2 AOC-SLG4-4E4T-O | 1 | 22 NVMe Support Kit for X12 Ultra 220U-TNR with NIC UIO | |
CBL-KIT-220U-TNR-8 | 1 | 8 NVMe Support Kit for X12 Ultra SYS-220U-TNR | |
Optional Storage Controller Card + Cable(s) | AOC-S3108L-H8iR-16DD + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; RAID 0, 1, 5, 6, 10, 50, 60 |
AOC-S3908L-H8iR-16DD-O + 1x CBL-SAST-1276F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3008L-L8i + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; RAID 0,1,1E | |
AOC-S3916L-H16iR-32DD-O + 1x CBL-SAST-1264F-100, 1x CBL-SAST-1276F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 16 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3008L-L8E+-O + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA + I2C | |
AOC-S3008L-L8E + 1x CBL-SAST-1260-100 or AOC-S3008L-L8E + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA | |
AOC-S3808L-L8iT-O + 1x CBL-SAST-1264F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-4; HBA | |
AOC-S3816L-L16iT-O + 2x CBL-SAST-1264F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 16 internal ports (12Gb/s) Gen-4; HBA | |
Power Supply | PWS-1K30D-1R • | 2 | 1U 1300W, Redundancy, DC Input: -48Vdc |
PWS-2K08A-1R • | 2 | 1U 2000W, Titanium Level, Redundancy, AC Input: 90-264VAC/47-63Hz, and wide DC input 180Vdc~300Vdc | |
Riser Card | RSC-W2-688G4 | 1 | 2U LHS WIO Riser card with one PCIe 4.0 x16 and two PCIe 4.0 x8 |
RSC-W2-66G4 | 1 | 2U LHS WIO Riser card with two PCIe 4.0 x16 slots,HF,RoHS | |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
Trusted Platform Module Options | AOM-TPM-9670V-S-FIPS-P | 1 | AOM-TPM-9670V-S-FIPS TPM 2.0 support TAA and FIPS,RoHS |
AOM-TPM-9671V-O | 1 | SPI Capable Vertical TPM 1.2 Module | |
AOM-TPM-9670V-O | 1 | SPI TPM 2.0 using SLB9670 | |
Ultra Riser Card Options + Rear Window | AOC-2UR668G4-O | 1 | 2U Ultra Riser with 2x PCIe 4.0 x16 and 1x PCIe 4.0 x8 (internal, in x16),RoHS |
AOC-2UR68G4-I2XT-O + MCP-240-82909-0N | 1 | 2U Ultra Riser with 2-port 10G RJ45, Intel Carlsville X710-AT2, 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0×8 (internal, in x16),RoHS | |
AOC-2UR68G4-I4XTS-O + MCP-240-82930-0N | 1 | 2U Ultra Riser with 2-port 10G RJ45 & 2-port 10G SFP+, Intel Carlsville X710-TM4, with 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0×8 (internal, in x16),RoHS | |
AOC-2UR68G4-M2TS + MCP-240-82914-0N | 1 | 2U Ultra Riser 2-port 25GbE SFP28, Mellanox CX-6 LX, 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0×8 (internal, in x16),RoHS |
Packing Information
Ultra SuperServer SYS-220U-TNR is sealed in Brocade original box. We will also pack SuperServer SYS-220U-TNR the second box before shipping.
![](https://ciscoswitchdna.com/wp-content/uploads/2022/07/photobank.webp)
Shipment
Our products will be sent via FedEx,DHL,TNT,UPS,EMS,and so on.but the buyer is responsible for
customs clearance and pay tariff when the product arrived destination country.
Shipping Methods
![](https://ciscoswitchdna.com/wp-content/uploads/2022/07/DHL_logo.webp)
2-4 business days
![](https://ciscoswitchdna.com/wp-content/uploads/2022/07/TNT_Express_Logo.webp)
2-4 business days
![](https://ciscoswitchdna.com/wp-content/uploads/2022/07/fedex_logo.webp)
2-4 business days
![](https://ciscoswitchdna.com/wp-content/uploads/2022/07/ems_logo.webp)
Reviews