Supermicro Ultra SuperServer SYS-220U-TNR
Key Applications |
Virtualization |
HPC |
Cloud Computing |
High End Enterprise Server |
Software Defined Storage |
Application Tier Service Provider |
5G/Telco |
Key Features |
Dual Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable Processors |
Intel® C621A Chipset |
32 DIMM Slots; |
Up to 8TB DRAM; |
Up to 8TB Intel® Optane™ Persistent Memory (up to 12TB with DRAM); |
3200/2933/2666 ECC DDR4 LRDIMM;RDIMM; |
Product SKUs | |
SuperServer SYS-220U-TNR (Black Front & Silver Body) | |
Motherboard | |
Super X12DPU-6 | |
Processor | |
CPU | Dual Socket P+ (LGA-4189) |
3rd Gen Intel® Xeon® Scalable processors | |
Support CPU TDP 270W * | |
Cores | Up to 40C/80T; Up to 60MB Cache |
Note | *Certain CPUs with high TDP may be supported only under specific conditions. Please contact Supermicro Technical Support for additional information about specialized system optimization |
System Memory | |
Memory | Memory Capacity: 32 DIMM slots |
Up to 8TB: 32x 256 GB DRAM | |
Up to 12TB: 16x 512 GB PMem and 16x 256 GB DRAM | |
Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM;LRDIMM | |
Intel® Optane™ persistent memory 200 series | |
Memory Voltage | 1.2 V |
Error Detection | ECC |
On-Board Devices | |
SATA | SATA3 (6Gbps) via Intel® PCH 621A; RAID 0/1/5/10 support |
NVMe | NVMe (16GT/s); RAID 0/1/5/10 support |
NVMe (16GT/s); RAID 0/1/5/10 support | |
Chipset | Intel® C621A |
Network Connectivity | 2x 10GbE BaseT with Intel® X710-AT2 (optional) OR |
2x 10GbE BaseT and 2x 10GbE SFP+ with Intel® X710-TM4 (optional) | |
No NIC option supported | |
IPMI | Support for Intelligent Platform Management Interface v.2.0 |
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support | |
Input / Output | |
LAN | 1 RJ45 Dedicated BMC LAN port |
USB | 2 USB 3.0 port(s) (2 rear) |
Video | 1 VGA port(s) |
Serial Port | 1 COM Port(s) (1 rear) |
DOM | 2 SuperDOM (Disk on Module) port |
System BIOS | |
BIOS Type | AMI 32MB SPI Flash EEPROM |
Management | |
Software | Supermicro Out of Band (OOB) License (Included with Server) |
Redfish API | |
IPMI 2.0 | |
Intel® Node Manager | |
KVM with dedicated LAN | |
SUM | |
NMI | |
Watch Dog | |
SuperDoctor® 5 | |
Power Configurations | ACPI Power Management |
Power-on mode for AC power recovery | |
PC Health Monitoring | |
CPU | 7 +1 Phase-switching voltage regulator |
Monitors for CPU Cores, Chipset Voltages, Memory | |
FAN | Fans with tachometer monitoring |
Pulse Width Modulated (PWM) fan connectors | |
Status monitor for speed control | |
Temperature | Monitoring for CPU and chassis environment |
Thermal Control for fan connectors | |
Chassis | |
Form Factor | 2U Rackmount |
Model | CSE-219U3TS-R1K62P-T |
Dimensions and Weight | |
Height | 3.5″ (89mm) |
Width | 17.2″ (437mm) |
Depth | 28.2″ (717.2mm) |
Package | 9.96″ (H) x 24.6″ (W) x 45.43″ (D) |
Weight | Net Weight: 37 lbs (16.8 kg) |
Gross Weight: 63 lbs (28.6 kg) | |
Available Color | Black Front & Silver Body |
Front Panel | |
Buttons | Power On/Off |
UID button | |
LEDs | HDD activity |
LAN1 activity | |
LAN2 acticity | |
Power Fail | |
Power status | |
System information (overheat/UID) | |
Expansion Slots | |
PCI-Express (PCIe) | 1 PCIe 4.0 x16 FH, 10.5″L slot(s) |
5 PCIe 4.0 x8 FH, 10.5″L slot(s) | |
1 PCIe 4.0 x8 Internal LP slot(s) | |
1 PCIe 4.0 x16 LP slot(s) | |
Note | Optional RSC-W2-66G4 enables PCIe x16 in slots 5, 7. Slots 6,8 will be disabled. |
Drive Bays / Storage | |
Hot-swap | 24x 2.5″ hot-swap NVMe/SATA/SAS drive bays (22x 2.5″ NVMe hybrid) (SAS/NVMe support requires additional parts. Please see the Optional Parts list.) |
System Cooling | |
Fans | 4x 8cm heavy duty fans with optimal fan speed control |
Air Shroud | 2 Air Shroud(s) |
Power Supply | |
1U 1600W Redundant Titanium AC Power Supply with PMbus 73.5x203x40mm | |
Dimension | 73.5 x 40 x 203 mm |
(W x H x L) | |
AC Input | 1000W: 100-127Vac / 50-60Hz |
1600W: 200-240Vac / 50-60Hz | |
+12V | Max: 83A / Min: 0A (100Vac-127Vac) |
Max: 133A / Min: 0A (200Vac-240Vac) | |
12V SB | Max: 2.1A / Min: 0A |
Output Type | Gold Finger Connector |
Certification | Titanium Level |
[ Test Report ] | |
Operating Environment | |
Environmental Spec. | Operating Temperature: |
10°C ~ 35°C (50°F ~ 95°F) | |
Non-operating Temperature: | |
-40°C to 60°C (-40°F to 140°F) | |
Operating Relative Humidity: | |
8% to 90% (non-condensing) | |
Non-operating Relative Humidity: | |
5% to 95% (non-condensing) |
Specification
Standard Parts (Parts Included) | |||
Part Number | Qty | Description | |
Motherboard / Chassis | MBD-X12DPU-6 | 1 | Super X12DPU-6 Motherboard |
CSE-219U3TS-R1K62P-T | 1 | 2U Chassis | |
Backplane | BPN-NVME4-216N-S24 | 1 | 2U 24-slot all-hybrid direct-attached backplane, support 24x 2.5 |
Cable | CBL-CDAT-0674 | 2 | 4 Pin to 4 Pin I2C Cable, 30cm, 26AWG, 4 Wires, Pinout 1-1 |
CBL-PWEX-0924 | 1 | 2×4,P3.0 to 2×4,P4.2,YL/RED,9.5A,24cm,16AWG,RoHS | |
CBL-PWEX-0925 | 2 | 2×4,P3.0 to 2×4,P4.2,YL/RED,9.5A,55cm,16AWG,RoHS | |
CBL-SAST-1250F-100 | 2 | Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,50CM,100 | |
CBL-SAST-1270F-100 | 1 | Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,70CM,100 | |
CBL-0088L | 4 | 10.5″ 4PIN FAN POWER CORD FOR 743X-645,PBF | |
CBL-0160L | 2 | US POWER CORD 16AWG, PB FREE | |
Riser Card | RSC-W2-8888G4 | 1 | 2U LHS WIO Riser card with four PCIe 4.0 x8 slots,HF,RoHS |
RSC-WR-6 | 1 | 1U RHS WIO Riser card with one PCIe 4.0 x16 slot,HF,RoHS | |
Software | SFT-OOB-LIC | 1 | License key for enabling OOB BIOS management |
Heatsink / Retention | SNK-P0078P | 2 | 2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-1K62A-1R | 2 | AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 – 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH |
*Drive Tray(s) | MCP-220-00047-0B | 24 | Black gen 3rd hot-swap 2.5inch HDD tray |
*Rail Set | MCP-290-00057-0N | 1 | Rail set, quick/quick, default for 4U 17.2″ W |
MCP-290-00060-0N | 1 | Threaded rail adapter default for round hole rack | |
MCP-290-00115-0N | 1 | Inner rail, quick-release type | |
MCP-290-00117-0N | 1 | Outer rail, quick-release type | |
*Air Shroud | MCP-310-81905-0B | 1 | Plastic air shroud for SC819U, 119U, 829U, 219U (PWS),RoHS/REACH |
*Fan | FAN-0209L4 OR | 4 | 80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above |
FAN-0206L4 | 80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers | ||
Notes: | |||
Parts with * are inside the chassis | |||
Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables…..etc. | |||
Optional Parts List | |||
Part Number | Qty | Description | |
2 Rear 2.5″ Hot-swap SATA Drive Bays (Complete System Only) | MCP-240-82922-0N-OEM • | 1 | Rear 2x 2.5″ HDDs riser bracket kit for SC829U/219U, tool-less |
2U Cable Management Arm | MCP-290-00128-0N & | 1 | 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42″ in depth) |
MCP-290-00127-0N | |||
2U Front Bezel | MCP-210-82601-0B • | 1 | Black Front Bezel Suitable for 829U and 219U chassis with standard thumbscrew handle. |
Add-on card for M.2 support | AOC-SLG3-2H8M2-O | – | 2x Hybrid NVMe/SATA M.2 RAID Carrier, Standard LP,RoHS |
CacheVaults | BTR-CVPM05 + BKT-BBU-BRACKET-05 | – | CacheVault for Broadcom 3908/3916 with Supercap |
BTR-CV3108-U1 | – | CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra | |
Drive Tray | MCP-220-00167-0B • | 1 ~ 22 | 2.5 drive tray, Orange tab (for hotswap NVMe drive) |
Global Services & Support | OSNBD3/2/1 | – | 3/2/1-year onsite NBD service |
OS4HR3/2/1 | – | 3/2/1-year onsite 24x7x4 service | |
Intel® VROC RAID Key Options | AOC-VROCINTMOD | 1 | Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) |
AOC-VROCPREMOD • | 1 | Intel VROC Premium, RAID 0, 1, 5, 10 | |
AOC-VROCSTNMOD | 1 | Intel VROC Standard, RAID 0, 1, 10 | |
Network Card(s) | AOC Compatibility Matrix | – | Standard Networking AOC Matrix |
NVMe Support Kit | CBL-KIT-220U-TNR-22N + 3 AOC-SLG4-4E4T-O | 1 | 22 NVMe Support Kit for X12 Ultra 220U-TNR without NIC UIO |
CBL-KIT-220U-TNR-22 + 2 AOC-SLG4-2E4T-O + 2 AOC-SLG4-4E4T-O | 1 | 22 NVMe Support Kit for X12 Ultra 220U-TNR with NIC UIO | |
CBL-KIT-220U-TNR-8 | 1 | 8 NVMe Support Kit for X12 Ultra SYS-220U-TNR | |
Optional Storage Controller Card + Cable(s) | AOC-S3108L-H8iR-16DD + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; RAID 0, 1, 5, 6, 10, 50, 60 |
AOC-S3908L-H8iR-16DD-O + 1x CBL-SAST-1276F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3008L-L8i + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; RAID 0,1,1E | |
AOC-S3916L-H16iR-32DD-O + 1x CBL-SAST-1264F-100, 1x CBL-SAST-1276F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 16 internal ports (12Gb/s) Gen-4; RAID 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3008L-L8E+-O + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA + I2C | |
AOC-S3008L-L8E + 1x CBL-SAST-1260-100 or AOC-S3008L-L8E + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA | |
AOC-S3808L-L8iT-O + 1x CBL-SAST-1264F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-4; HBA | |
AOC-S3816L-L16iT-O + 2x CBL-SAST-1264F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 16 internal ports (12Gb/s) Gen-4; HBA | |
Power Supply | PWS-1K30D-1R • | 2 | 1U 1300W, Redundancy, DC Input: -48Vdc |
PWS-2K08A-1R • | 2 | 1U 2000W, Titanium Level, Redundancy, AC Input: 90-264VAC/47-63Hz, and wide DC input 180Vdc~300Vdc | |
Riser Card | RSC-W2-688G4 | 1 | 2U LHS WIO Riser card with one PCIe 4.0 x16 and two PCIe 4.0 x8 |
RSC-W2-66G4 | 1 | 2U LHS WIO Riser card with two PCIe 4.0 x16 slots,HF,RoHS | |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
Trusted Platform Module Options | AOM-TPM-9670V-S-FIPS-P | 1 | AOM-TPM-9670V-S-FIPS TPM 2.0 support TAA and FIPS,RoHS |
AOM-TPM-9671V-O | 1 | SPI Capable Vertical TPM 1.2 Module | |
AOM-TPM-9670V-O | 1 | SPI TPM 2.0 using SLB9670 | |
Ultra Riser Card Options + Rear Window | AOC-2UR668G4-O | 1 | 2U Ultra Riser with 2x PCIe 4.0 x16 and 1x PCIe 4.0 x8 (internal, in x16),RoHS |
AOC-2UR68G4-I2XT-O + MCP-240-82909-0N | 1 | 2U Ultra Riser with 2-port 10G RJ45, Intel Carlsville X710-AT2, 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0×8 (internal, in x16),RoHS | |
AOC-2UR68G4-I4XTS-O + MCP-240-82930-0N | 1 | 2U Ultra Riser with 2-port 10G RJ45 & 2-port 10G SFP+, Intel Carlsville X710-TM4, with 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0×8 (internal, in x16),RoHS | |
AOC-2UR68G4-M2TS + MCP-240-82914-0N | 1 | 2U Ultra Riser 2-port 25GbE SFP28, Mellanox CX-6 LX, 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0×8 (internal, in x16),RoHS |
Packing Information
Ultra SuperServer SYS-220U-TNR is sealed in Brocade original box. We will also pack SuperServer SYS-220U-TNR the second box before shipping.
Shipment
Our products will be sent via FedEx,DHL,TNT,UPS,EMS,and so on.but the buyer is responsible for
customs clearance and pay tariff when the product arrived destination country.
Reviews
There are no reviews yet.