SuperServer 6029BT-HNC0R
Schlüsselanwendungen – Compute Intensive Application |
– HPC, Rechenzentrum, Unternehmen |
Server |
– Hyperscale / Hyperconverged |
Hauptmerkmale |
Four hot-pluggable systems (nodes) in a 2U form factor. Each node supports the following: |
1. Doppelsteckdose P (LGA 3647) Unterstützung |
2Skalierbarer Intel® Xeon® der 2. Generation |
Prozessoren (Cascade Lake/Skylake)‡ |
2. 24 DIMMs; up to 6TB 3DS ECC |
DDR4-2933MHz† RDIMM/LRDIMM, |
Supports Intel® Optane™ DCPMM†† |
3. 2 PCI-E 3.0 x16 (LP) Slot; 1 SIOM |
card support (flexible networking) |
Notiz: must bundle with Network card |
4. 3 Hot-Swap 3.5″ NVMe/SAS3 drive bays; |
2 M.2 SATA3 or NVMe support |
5. SAS3 support via Broadcom 3008; |
IT mode |
6. 1 Carrier Card slot (M.2 support) |
7. IPMI 2.0 + KVM with dedicated LAN |
8. Video via Aspeed AST2500 BMC |
9. 4 Heavy duty 8cm PWM fans with |
air shroud |
10. 2200W Redundante Netzteile |
Titanniveau (96%) |
Product SKUs | |
SYS-6029BT-HNC0R | SuperServer 6029BT-HNC0R (Schwarz) |
Hauptplatine | |
Super X11DPT-B | |
Prozessor | |
CPU | Doppelsteckdose P (LGA 3647) |
2nd Gen Intel® Xeon® Scalable Processors and Intel® Xeon® Scalable Processors‡, | |
Dual UPI up to 10.4GT/s | |
Support CPU TDP 70-205W* | |
Kerne | Bis zu 28 Kerne |
Notiz | * Certain CPUs with high TDP may be supported only under specific conditions. Please contact Supermicro Technical Support for additional information about specialized system optimization. |
Notiz | ‡ BIOS version 3.2 oder höher ist erforderlich, um skalierbare Intel® Xeon® Prozessoren der 2. Generation zu unterstützen (Codename Cascade Lake-R) |
Systemspeicher | |
Speicherkapazität | 24 DIMM-Steckplätze |
Up to 6TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM | |
Supports Intel® Optane™ DCPMM†† | |
Speichertyp | 2933†/2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM |
Notiz | † 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro |
†† Cascade Lake only. Weitere Informationen erhalten Sie von Ihrem Supermicro-Vertriebsmitarbeiter. | |
On-Board Devices | |
Chipset | Intel® C621 chipset |
SAS | SAS3 (12Gbit/s) via Broadcom 3008; IT mode |
Netzwerk | Must bundle with at least one SIOM network card |
IPMI | Support for Intelligent Platform Management Interface v.2.0 |
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support | |
Video | ASPEED AST2500 BMC |
Eingang / Output (per Node) | |
LAN | 1 RJ45 Dedicated IPMI LAN port |
USB | 2 USB 3.0 Häfen (hinteren) |
Video | 1 VGA port |
DOM | 1 SuperDOM (Disk on Module) Hafen |
Others | M.2 and SATA DOM for boot drive only |
System BIOS | |
BIOS Type | AMI 32Mb SPI Flash ROM |
Management | |
Software | Intel® Node Manager |
IPMI 2.0 | |
KVM with dedicated LAN | |
SSM, SPM, SUM | |
SuperDoctor® 5 | |
Watch Dog | |
Power Configurations | ACPI / APM Power Management |
PC Health Monitoring | |
CPU | Monitors for CPU Cores, Chipset Voltages, Erinnerung. |
4+1 Phase-switching voltage regulator | |
LÜFTER | Fans with tachometer monitoring |
Status monitor for speed control | |
Pulse Width Modulated (PWM) fan connectors | |
Temperatur | Monitoring for CPU and chassis environment |
Thermal Control for fan connectors | |
Chassis | |
Formfaktor | 2U-Rackmount |
Modell | CSE-827BHQ+-R2K22BP |
Dimensions and Weight | |
Breite | 17.6″ (447mm) |
Höhe | 3.47″ (88mm) |
Tiefe | 30.11″ (765mm) |
Package | 9.76″ (H) x 24.65″ (W) x 45.28″ (D) |
Gewicht | Bruttogewicht: 86.5 Pfund (39.24 kg) |
Nettogewicht: 56 Pfund (25.4 kg) | |
Verfügbare Farben | Schwarz |
Front Panel | |
Tasten | Power On/Off button |
UID button | |
LEDs | Power status LED |
HDD activity LED | |
Network activity LEDs | |
Universal Information (UID) LED | |
Erweiterungssteckplätze (per Node) | |
PCI-Express | 2 PCI-E 3.0 (x16) Low-profile slots |
1 SIOM card support | |
(must bundle with network card) | |
Drive Bays / Lagerung (per Node) | |
Hot-swap | 3 Hot-Swap 3.5″ NVMe/SAS3 drive bays |
Please contact Supermicro Technical Support for additional information about HDD and SSD if mixed. Some restrictions and configuration rules that apply to SSD are different from HDD. | |
M.2 | 2 M.2 NVMe or SATA (2240/2260/2280) via optional AOC-SMG3-2H8M2-B |
System Cooling | |
Fans | 4 Heavy duty 8cm PWM fans with air shroud |
Stromversorgung | |
2200W Redundant Power Supplies with PMBus | |
Total Output Power | 1200W/1800W/1980W/2090/2200W |
Abmessungen | 45 X 40 X 480 mm |
(W x H x L) | |
Eingang | 1200W: 100-127Vac / 50-60Hz |
1800W: 200-220Vac / 50-60Hz | |
1980W: 220-230Vac / 50-60Hz | |
2090W: 230-240Vac / 50-60Hz | |
2090W: 180-220Vac (for UL/cUL only) | |
2200W: 220-240Vac (for UL/cUL only) | |
2090W: 230-240Vdc (for CCC only) | |
+12V | Max: 100A / Mindest: 0A (100-127Vac) |
Max: 150A / Mindest: 0A (200-220Vac) | |
Max: 165A / Mindest: 0A (220-230Vac) | |
Max: 174.17A / Mindest: 0A (230-240Vac) | |
Max: 174.17A / Mindest: 0A (180-220Vac, UL/cUL only) | |
Max: 183.33A / Mindest: 0A (220-240Vac, UL/cUL only) | |
Max: 174.17A / Mindest: 0A (230-240Vdc, CCC only) | |
12Vsb | Max: 2.1A / Mindest: 0A |
Output Type | Gold Finger |
Zertifizierung | Titanniveau |
[ Test Report ] | |
Operating Environment | |
RoHS | RoHS-konform |
Environmental Spec. | Betriebstemperatur: |
10°C ~ 35°C (50°F ~ 95°F) | |
Non-operating Temperature: | |
-40°C to 60°C (-40°F to 140°F) | |
Operating Relative Humidity: | |
8% Zu 90% (nicht kondensierend) | |
Non-operating Relative Humidity: | |
5% Zu 95% (nicht kondensierend) |
Spezifikation
Liste der Einzelteile – (Enthaltene Artikel) | |||
Artikelnummer | Menge | Beschreibung | |
Hauptplatine / Chassis | MBD-X11DPT-B | 4 | Super X11DPT-B Motherboard |
CSE-827BHQ+-R2K22BP | 1 | 2U-Chassis | |
Rückwandplatine | BPN-ADP-6S3008N4-1UB | 4 | Big Twin 1U hybrid ADP supporting 6x SAS3 and 4x NVMe |
Rückwandplatine | BPN-SAS3-827BHQ-N3 | 1 | 2U 12-Port 4-Node Hybrid Backplane Supports 3×3.5 |
Kabel 1 | CBL-PWCD-0578 | 2 | PWCD,US,IEC60320 C14 TO C13,3FT,14AWG |
Drive Tray(S) | MCP-220-00133-0B-BULK | 12 | Black gen 8 hot-swap 3.5 |
Teile | MCP-240-82718-0N | 1 | SC827B BigTwin type I (Impact) BPN retention bkt assy |
Air Shroud | MCP-310-21718-0B | 4 | Bigtwin air box for X11DPT-B(4pcs/set) |
Air Shroud | MCP-310-21724-0B | 4 | Bigtwin 2U4N plastic air shroud (2Stck) for Cascade lake MB |
Manual | MNL-2092-QRG | 1 | 6029BT-HNC0R Quick Reference Guide |
Riser Card | RSC-P-6 | 4 | RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS |
Riser Card | RSC-R1UTP-E16R | 4 | 1U RHS TwinPro Riser card with one PCI-E x16 slot |
Kühlkörper / Zurückbehaltung | SNK-P0067PS | 4 | 1Passiver U-CPU-Kühlkörper für die X11-Purley-Plattform, ausgestattet mit einem schmalen Haltemechanismus |
Kühlkörper / Zurückbehaltung | SNK-P0067PSM | 4 | 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism |
Lüfter | LÜFTER-0162L4 | 4 | 80x80x38 mm, 13.5K U/min, HCP, LMV, and LPC Cooling Fan |
Stromversorgung | PWS-2K22A-1R | 2 | 1U 2200W Redundant Power Supply Titanium, 45(W) X 40(H) X 48 |
Optionale Teileliste | |||
Artikelnummer | Menge | Beschreibung | |
Lüfter | LÜFTER-0191L4 | – | 80x80x38 mm, 14.9K U/min, Non-hot-swappable Middle Cooling Fan (Optimal for computational performance) |
3.5″ bis 2,5″ Converter Tray | MCP-220-00140-0B | – | Black gen 8 hot-swap 3.5-to-2.5 Tool-less HDD tray, orange tab |
TPM security module | AOM-TPM-9670H-S | 1 | SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor |
TPM security module | AOM-TPM-9671H-S | 1 | SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor |
Intel VROC RAID Key | AOC-VROCINTMOD | 1 | Intel VROC, ÜBERFALL 0, 1, 5, 10 (Intel SSD Only) |
AOC-VROCSTNMOD | 1 | Intel VROC Standard, ÜBERFALL 0, 1, 10 | |
AOC-VROCPREMOD | 1 | Intel VROC Premium, ÜBERFALL 0, 1, 5, 10 | |
Globale Dienste & Unterstützung | OS4HR3/2/1 | – | 3/2/1-Jahr Vor-Ort-Service rund um die Uhr |
OSNBD3/2/1 | – | 3/2/1-Jahr Vor-Ort-NBD-Service | |
Software | SFT-OOB-LIC • | 1 | OOB-Verwaltungspaket (pro Knotenlizenz) |
Software | SFT-DCMS-Single | 1 | DataCenter-Verwaltungspaket (pro Knotenlizenz) |
SuperDOM | – | – | Supermicro SATA DOM Solutions [Details] |
Network Card(S) | AOC-S40G-i2Q | – | Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 |
AOC-SGP-i2 | – | Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 | |
AOC-SGP-i4 | – | Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 | |
AOC-STG-b4S | – | Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S | |
AOC-STGN-i2S | – | Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES | |
AOC-STGN-i1S | – | Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN | |
AOC-STG-i2T | – | Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 | |
AOC-STG-i2 | – | Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB | |
Carrier Card(S) | AOC-SMG3-2H8M2-B | – | 2x Hybrid NVMe/SATA M.2 carrier for BigTwin,HF,RoHS |
AOC-SMG2-2TM2 | – | 2x SATA M.2 RAID 1 adapter for BigTwin,HF,RoHS |
Verpackungsinformationen
SuperServer 6029BT-HNC0R is sealed in Brocade original box. We will also pack SuperChassis 6029BT-HNC0R the second box before shipping.

Sendung
Unsere Produkte werden per FedEx versendet,DHL,TNT,UPS,EMS,und so weiter. aber der käufer ist verantwortlich für
Zollabfertigung und Zahlung des Tarifs, wenn das Produkt im Zielland ankommt.
Versandarten

2-4 Arbeitstage

2-4 Arbeitstage

2-4 Arbeitstage

Bewertungen
Es gibt noch keine Bewertungen.