Cisco provides two modes of operation for Cisco Nexus 9000 Series Switches. Organizations can deploy Cisco Application Centric Infrastructure (Cisco ACI™) or Cisco Nexus switch environments (Cisco NX-OS mode). The Cisco ACI solution is a holistic, intent-driven architecture with centralized automation and policy-based application profiles. It provides a robust, transport network for dynamic workloads and is built on a network fabric that combines time-tested protocols with new innovations to create a highly flexible, scalable, and resilient architecture of low-latency, high-bandwidth links. This fabric delivers a network that can support the most demanding and flexible data center environments.
N9K-C93600CD-GX is the Cisco Nexus 9316D Spine and Leaf switch with 28p 100/40G QSFP28 and 8p 400/100G QSFP-DD. Based on Cisco® Cloud Scale technology, the Cisco Nexus® 9300-GX switches are the next generation of fixed Cisco Nexus 9000 Series Switches. The platform introduces a fully backward-compatible 400G optical interface Quad Small Form-Factor Pluggable – Double Density (QSFP-DD) to transparently migrate existing data center fabrics from 40-Gbps and 100-Gbps speeds to 400 Gbps. The platform provides investment protection for customers, delivering highly flexible layer 2 and layer 3 scalability, and performance to meet the changing needs of virtualized data centers and automated cloud environments.
Specification
N9K-C93600CD-GX Specification | |
---|---|
Ports | ● 28 x 100/40-Gbps QSFP28 ports and 8 x 400/100-Gbps QSFP-DD ports |
Physical | ● System memory: 16 GB NX-OS, 24 GB ACI ● Solid-State Disk (SSD): 128 GB ● USB: 1 port ● RS-232 serial console ports: 1 ● Management ports: 2 (1 x 10/100/1000BASE-T and 1 x 1-Gbps SFP+) ● Broadwell-DE CPU: 4 cores ● Dimensions (H x W x D): 1.72 x 17.37 x 25.5 in. (4.37 x 44.13 x 64.8 cm) |
Packet buffer | ● 80 MB centralized buffer |
Cooling | ● Fans: NXA-FAN-35CFM-PI and NXA-FAN-35CFM-PE ● 5+1 redundancy ● Port-side intake or port-side exhaust airflow direction ● Hot swappable: Yes |
Power | ● AC: ◦ 1100W Watt (W) AC power supplies (up to 2) ◦ 1+1 redundancy ◦ 80 Plus Platinum-rated power supplies with efficiency of 90% or greater (20 to 100% load) ◦ Frequency: 50 to 60 Hz (AC) ◦ RoHS compliance: Yes ◦ Hot swappable: Yes ◦ Port-side intake or port-side exhaust options ◦ Typical power: 590W ● DC: ◦ 1100 Watt (W) DC power supplies (up to 2) ◦ 1+1 redundancy ◦ 80 Plus Platinum-rated power supplies with efficiency of 90% or greater (20 to 100% load) ● High-voltage AC/DC ◦ Power: 1100W AC, 930W DC, or 1200W HVAC/HVDC ◦ Input voltage: 100 to 240V * AC or –40 to –72V DC (minimum and maximum), –48 to –60V DC (nominal) |
Environmental | ● Operating temperature: 32 to 104°F (0 to 40°C) ● Nonoperating (storage) temperature: -40 to 158°F ● (-40 to 70°C) ● Humidity: 5 to 85% (noncondensing) ● Altitude: 0 to 13,123 ft (0 to 4000m) |
Maximum number of IPv4 Longest Prefix Match (LPM) routes | 896,000 |
Maximum number of IPv4 host entries | 896,000 |
Maximum number of MAC address entries | 256,000 |
Maximum number of multicast routes | 32,000 |
Number of Interior Gateway Management Protocol (IGMP) snooping groups | Shipping: 8000 Maximum: 32,000 |
Maximum number of Access-Control-List (ACL) entries | Per slice of the forwarding engine: ● 5000 ingress ● 2000 egress ● Max: 20,000 ingress, 8000 egress |
Maximum number of VLANs | 3967 |
Number of Virtual Routing and Forwarding (VRF) instances | Shipping: 1000 Maximum: 16,000 |
Maximum number of ECMP paths | 64 |
Maximum number of port channels | 512 |
Maximum number of links in a port channel | 32 |
Number of active SPAN sessions | 4 |
Maximum number of VLANs in Rapid per-VLAN Spanning Tree (RPVST) instances | 3967 |
Maximum number of Hot-Standby Router Protocol (HSRP) groups | 490 |
Maximum number of Multiple Spanning Tree (MST) instances | 64 |
Flow-table size used for Cisco Tetration Analytics platform | 64,000 |
Number of Network Address Translation (NAT) entries | 1023 |
Regulatory compliance | Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC. |
Safety | ● UL 60950-1 Second Edition ● CAN/CSA-C22.2 No. 60950-1 Second Edition ● EN 60950-1 Second Edition ● IEC 60950-1 Second Edition ● AS/NZS 60950-1 ● GB4943 |
EMC: Emissions | ● 47CFR Part 15 (CFR 47) Class A ● AS/NZS CISPR22 Class A ● CISPR22 Class A ● EN55022 Class A ● ICES003 Class A ● VCCI Class A ● EN61000-3-2 ● EN61000-3-3 ● KN22 Class A ● CNS13438 Class A Note: Cisco Nexus N9K-C9364C passes EMC Radiated Emissions standards in all configurations, with the only exception being if more than 40 pluggable optics of Cisco part number 10-3142-02 (or 10-3142-01) are used. |
EMC: Immunity | ● EN55024 ● CISPR24 ● EN300386 ● KN 61000-4 series |
RoHS | The product is RoHS-6 compliant with exceptions for leaded Ball Grid-Array (BGA) balls and lead press-fit connectors. |
Packing Information
Cisco Nexus 9000 Series switch N9K-C93600CD-GX is sealed in cisco original box. We will also pack N9K-C93600CD-GX with the second box before shipping.
Shipment
Our products will be sent via FedEx,DHL,TNT,UPS,EMS,and so on.but the buyer is responsible for
customs clearance and pay tariff when the product arrived destination country.
Reviews
There are no reviews yet.