The Cisco Nexus 3172PQ switch is a dense, high-performance Layer 2 and 3 10 and 40-Gbps switch that is a member of the Cisco Nexus 3100 switches. The Cisco Nexus 3172PQ is well suited for data centers that require a cost-effective, power-efficient line-rate Layer 2 and 3 top-of-rack (ToR) switch.
Specification
N3K-C3172PQ-10GE Specifications | |||
---|---|---|---|
Physical | ● 1RU fixed form factor ● 72 x 10 Gigabit Ethernet ports (48 SFP+ and 6 QSFP+) ◦ 48 SFP ports support 1 and 10 Gigabit Ethernet ◦ 6 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each ● Redundant fans (3+1) ● 2 redundant power supplies ● Management, console, and USB flash-memory ports |
||
Performance | ● 1.4-Tbps switching capacity ● Forwarding rate of up to 1 bpps ● Line-rate traffic throughput (both Layer 2 and 3) on all ports ● Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
||
Hardware tables and scalability | Number of MAC addresses | 288,000 | |
Number of VLANS | 4096 | ||
Number of spanning-tree instances | ● RSTP: 512 ● MSTP: 64 |
||
Number of ACL entries | ● 4000 ingress ● 1000 egress |
||
Routing table | ● 16,000 prefixes and 16,000 host entries* ● 8000 multicast routes* |
||
Number of EtherChannels | 64 (with vPC) | ||
Number of ports per EtherChannel | 32 | ||
System memory | 4 GB | ||
Buffer size | 12 MB shared | ||
Boot flash | 16 GB | ||
Power | Number of power supplies | 2 | |
Power supply types | ● AC (forward and reversed airflow) ◦ – N2200-PAC-400W and N2200-PAC-400W-B (PQ models) ◦ – NXA-PAC-500W and NX-PAC-500W-B (TQ models) ● DC (forward and reversed airflow) ◦ – N2200-PDC-400W and N3K-PDC-350W-B (PQ models) ◦ – NXA-PDC-500W and NX-PDC-500W-B (TQ models) |
||
Typical operating power | 143 W | ||
Maximum power | 293W | ||
AC PSUs ● Input voltage ● Frequency ● Efficiency |
● 100 to 240 VAC ● 50 to 60 Hz ● 89 to 91% at 220V |
||
DC PSUs ● Input voltage ● Maximum current (PSU output – System input) ● Efficiency |
● –40 to –72 VDC ● 33A (400W unit), 42A (500W unit) ● 85 to 88% |
||
Cooling | ● Forward and reversed airflow schemes: ◦ Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports) ◦ Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies) ● Redundant fans ● Hot swappable (must swap within 1 minute) |
||
Sound | Measured sound power (maximum) ● Fan speed: 40% duty cycle ● Fan speed: 70% duty cycle ● Fan speed: 100% duty cycle |
● 64.9 dBA ● 69.3 dBA ● 76.7 dBA |
|
Environment | Dimensions (height x width x depth) |
1.72 x 17.3 x 17 in. (4.4 x 43.9 x 43.2 cm) | |
Weight | 18.6 lb (8 4 kg) | ||
Operating temperature | ● 32 to 104°F (0 to 40°C) | ||
Storage temperature | ● -40 to 158°F (-40 to 70°C) | ||
Operating relative humidity | ● 10 to 85% noncondensing ● Up to 5 days at maximum (85%) humidity ● Recommend ASHRAE data center environment |
||
Storage relative humidity | ● 5 to 95% noncondensing | ||
Altitude | ● 0 to 10,000 ft (0 to 3000m) | ||
Safety and EMC | |||
Regulatory compliance | ● Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC. | ||
Safety | ● UL 60950-1 Second Edition ● CAN/CSA-C22.2 No. 60950-1 Second Edition ● EN 60950-1 Second Edition ● IEC 60950-1 Second Edition ● AS/NZS 60950-1 ● GB4943 |
||
EMC: Emissions | ● 47CFR Part 15 (CFR 47) Class A ● AS/NZS CISPR22 Class A ● CISPR22 Class A ● EN55022 Class A ● ICES003 Class A ● VCCI Class A ● EN61000-3-2 ● EN61000-3-3 ● KN22 Class A ● CNS13438 Class A |
||
EMC: Immunity | ● EN55024 ● CISPR24 ● EN300386 ● KN24 |
||
RoHS | ● RoHS 5 compliant except for lead press-fit connectors |
Packing InformationCisco Nexus 3000 Series switch N3K-C3172PQ-10GE is sealed in cisco original box. We will also pack N3K-C3172PQ-10GE with the second box before shipping.
Shipment
Our products will be sent via FedEx,DHL,TNT,UPS,EMS,and so on.but the buyer is responsible for
customs clearance and pay tariff when the product arrived destination country.
Reviews
There are no reviews yet.