The Cisco Nexus® 9000 Series Switches operate in one of two modes – Cisco Application Centric Infrastructure (Cisco ACI™) or Cisco NX-OS. In Cisco ACI mode, these switches provide a turnkey, fully automated, policy-based architecture to design and manage data center fabrics. In Cisco NX-OS mode, these switches provide the capability to use foundational layer 2/3 technologies, as well as modern technologies such as VXLAN, with a Border Gateway Protocol‒Ethernet VPN (BGP-EVPN) control plane, Segment routing, Multiprotocol Label Switching (MPLS), and automation via NX-APIs.
Product Details
The Cisco Nexus 9000 Series Switches provides features and benefits:
* High performance
The Cisco Nexus 9500 Series switch delivers nonblocking performance at a latency of 5 microseconds or less at 400-, 100-, 50-, 40-, 25-, 10-, and 1-Gigabit Ethernet speeds. This enables customers to build robust and scalable high-speed fabrics that can support several thousands of high-speed access ports.
* Telemetry
The Cisco Nexus 9500 Series switches support extensive switch and flow telemetry capabilities that provide extensive real-time visibility into switch and fabric states.
* High-density 1-, 10-, 25-, 40- and 50-Gigabit Ethernet access configuration
Organizations can transition from low-speed (100-Megabit Ethernet and 1-Gigabit Ethernet) server access designs to high-speed (1-, 10-, 25-, 40-, and 50-Gigabit Ethernet) server access designs with the same port density.
* High-density 10-, 40-, 100- and 400-Gigabit Ethernet aggregation and spine configuration
The Cisco Nexus 9500 Series Switches help organizations transition from 1- and 10-Gigabit Ethernet infrastructure to 10-, 40-, 100-, and 400-Gigabit Ethernet infrastructures to support the increased bandwidth demands of scale-out, multinode application environments. The compatibility of 400-Gigabit Ehternet QSFP-DD modules, 100-Gigabit Ethernet QSFP28 modules, and 40-Gigabit Ethernet QSFP+ modules enables the migration and coexistence of 40-, 100- and 400-Gigabit Ethernet ports in the fabric.
* High availability, reliability, and scalability
The Cisco Nexus 9500 Series Switches are designed with redundant supervisors, system controllers, power supplies, and fan trays, which eliminate any single point of failure in the chassis. These switches also support up to 6 fabric modules, which provide redundancy and graceful degradation of switching capacity in the event of fabric module failures. All transceivers are pluggable to support the highest possible Mean Time Between Failure (MTBF) for the switch.
* Designed for the future
The Cisco Nexus 9500 Series Switches are designed for future expansion with the capability to support higher speed ports and more bandwidth.
* Power efficiency
The Cisco Nexus 9500 Series Switches are the first switch chassis designed without a midplane. The line cards and fabric modules connect directly. This revolutionary design provides optimal front-to-back airflow and helps the switch operate with less power. In addition, all Cisco Nexus 9500 Series switch power supplies are rated at or higher than 80PLUS Platinum for AC inputs and equivalent efficiency for DC inputs.
The typical power consumption per 10-Gigabit Ethernet port is less than 3.5 watts (W).
The typical power consumption per 40-and 100-Gigabit Ethernet port is less than 14W and 22W respectively.
Specification
N9K-C9516 Specification | |
---|---|
Chassis | ● Up to 16 line cards ● Up to 10 power supplies ● Up to 6 fabric modules of the same type ● Up to 2 system controllers ● Up to 2 supervisors of the same type ● Up to 3 fan trays |
Number of line card slots | 16 |
Physical (H x W x D) | 36.70 x 17.50 x 31.76 in. (93.41 x 44.50 x 80.67 cm) |
Weight (chassis) | 192 lb (87.3 kg) |
Operating temperature | 32 to 104°F (0 to 40°C) |
Nonoperating (storage) temperature | -40 to 158°F (-40 to 70°C) |
Rack Units | 21 |
Mean Time Between Failure (MTBF) Hours | 680,000 |
Humidity | 5 to 95% (noncondensing) |
Altitude | 0 to 13,123 ft (0 to 4000m) |
Regulatory compliance | Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC |
Safety | ● UL 60950-1 Second Edition ● CAN/CSA-C22.2 No. 60950-1 Second Edition ● EN 60950-1 Second Edition ● IEC 60950-1 Second Edition ● AS/NZS 60950-1 ● GB4943 |
EMC: Emissions | ● 47CFR Part 15 (CFR 47) Class A ● AS/NZS CISPR22 Class A ● CISPR22 Class A ● EN55022 Class A ● ICES003 Class A ● VCCI Class A ● EN61000-3-2 ● EN61000-3-3 ● KN22 Class A ● CNS13438 Class A |
EMC: Immunity | ● EN55024 ● CISPR24 ● EN300386 ● KN 61000-4 series |
RoHS | The product is RoHS-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. |
Packing Information
Cisco Nexus 9500 Series switch N9K-C9516 is sealed in cisco original box. We will also pack N9K-C9516 with the second box before shipping.
Shipment
Our products will be sent via FedEx,DHL,TNT,UPS,EMS,and so on.but the buyer is responsible for
customs clearance and pay tariff when the product arrived destination country.
Reviews