Norme 5600 Série
8 and 16-port RS-232/422/485 rackmount serial device servers
With the NPort® 5600 Rackmount Series, you not only protect your current hardware investment, but also allow for future network expansion by centralizing the management of your serial devices and distributing management hosts over the network.
Network Readiness for up to 16 Serial Devices
Only basic configuration is needed with the NPort® 5600 to connect up to 16 serial devices to an Ethernet network.
19-Inch Rackmount Device Server
NPort® 5600 device servers come with Tx/Rx LEDs for the serial ports on the front panel, et 8 ou 16 RJ45 serial port connectors on the rear panel. This makes the NPort® 5600 device servers suitable for a standard 19-inch rackmount, allowing you to simplify operational, entretien, and administrative tasks.
Real COM/TTY Ports
Real COM/TTY drivers are provided to make the serial ports on the NPort® 5600 recognizable as Real COM ports by Windows, or Real TTY ports by Linux. In addition to supporting basic data transmission and reception, the NPort® drivers also support the RTS, CTS, DTR, DSR, and DCD control signals.
LED Indicators to Ease Your Maintenance Tasks
The System LED, serial Tx/Rx LEDs, and Ethernet LEDs (located on the RJ45 connector) provide a great tool for basic maintenance tasks and help engineers analyze problems in the field. The LEDs not only indicate current system and network status, but they also help field engineers monitor the status of attached serial devices.
Adjustable Termination and Pull High/Low Resistors
When using termination resistors to prevent serial signal reflection, it is important to set the pull high/low resistors correctly so that the electrical signal is not corrupted. Since no set of resistor values is universally compatible for all environments, the NPort® 5650-8/16 has DIP switches on the bottom panel for setting the termination and pull high/low resistor values.
NPort 5610-16-48V | NPort 5610-16-48V | Norme 5650-8 | Norme 5630-8 | Norme 5630-16 |
NPort 5650-16-M-SC | NPort 5650-16-M-SC | NPort 5650-16-T | NPort 5650-8-HV-T | NPort 5650-16-S-SC |
NPort 5650-8-M-SC | NPort 5650-8-M-SC | Norme 5610-8 | Norme 5610-16 | NPort 5610-8-48V |
NPort 5650-16-HV-T | NPort 5650-16-HV-T | NPort 5650-8-S-SC | Norme 5650-16 | NPort 5650-8-T |
spécification
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector) | 1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Magnetic Isolation Protection | 1.5 kv (built-in) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fibre optique |
|
Ethernet Software Features
Configuration Options | Telnet Console Web Console (HTTP/HTTPS) Windows Utility |
Gestion | ARP BOOTP DHCP Client DNS HTTP HTTPS ICMP IPv4 LLDP RFC2217 Rtelnet PPP SLIP SMTP SNMPv1/v2c TCP/IP Telnet UDP |
Filter | IGMP v1/v2c |
Windows Real COM Drivers | Windows 11/10/8.1/8/7/Vista/XP/ME/98/95 Windows Server 2022/2019/2016/2012 R2/2012/2008 R2/2008/2003 Windows Embedded CE 6.0/5.0, Windows XP Embedded |
Linux Real TTY Drivers | Kernel versions 6.x, 5.X, 4.X, 3.X, 2.6.X, and 2.4.x |
Fixed TTY Drivers | macOS Versions: 11.X, 10.12 pour 10.15 |
Arm®-based Platform Support | Linux Kernel 5.x/4.x |
VMWare ESXi (les fenêtres 11/10 | VMWare ESXi (les fenêtres 11/10) VMware Fusion (Windows on macOS 10.12 to 11.x) Parallels Desktop (Windows on macOS 10.12 to 11.x) |
Android API | Android 3.1.x and later |
Time Management | SNTP |
Security Functions
Authentification | Local database |
Chiffrement | HTTPS AES-128 RSA-1024 SHA-1 SHA-256 |
Security Protocols | HTTPS (TLS 1.2) SNMPv3 |
Interface série
Connecteur | 8-pin RJ45 |
Non. des ports | 8 ou 16 ports |
Normes série | Norme 5610 Des modèles: RS-232 Norme 5630 Des modèles: RS-422, RS-485 Norme 5650 Des modèles: RS-232, RS-422, RS-485 |
Operation Modes | Disabled Ethernet Modem Pair Connection Real COM Reverse Telnet RFC2217 TCP Client TCP Server UDP |
Baudrate | Supports standard baudrates (unit=bps): 50, 75, 110, 134, 150, 300, 600, 1200, 1800,2400, 4800,7200,9600, 19200, 38400, 57600, 115200, 230.4k, 460.8k, 921.6k |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 1.5, 2 |
Parité | Aucun, Even, Odd, Space, Mark |
Contrôle du débit | Aucun RTS/CTS (RS-232 only) DTR/DSR (RS-232 only) XON/XOFF |
Tirez une résistance haute / basse pour RS-485 | 1 kilo-ohm, 150 kilo-ohms |
Terminator pour RS-485 | 120 ohms |
Contrôle de direction des données RS-485 | Contrôle automatique de direction des données (Additionner) |
Signaux en série
RS-232 | Txd, Rxd, RTS, CTS, DTR, DSR, DCD, GND |
RS-422 | Tx +, Tx-, Rx +, Rx-, GND |
RS-485-4W | Tx +, Tx-, Rx +, Rx-, GND |
RS-485-2W | Données +, Données-, GND |
Paramètres de puissance
Courant d'entrée | NPort 5610-8-48V/16-48V: 135 ma @ 48 VCC NPort 5650-8-HV-T/16-HV-T: 152 ma @ 88 VCC Norme 5610-8/16: 141 ma @ 100 VCA Norme 5630-8/16: 152 ma @ 100 VCA NPort 5650-8/8-T/16/16-T: 158 ma @ 100 VCA NPort 5650-8-M-SC/16-M-SC: 174 ma @ 100 VCA NPort 5650-8-S-SC/16-S-SC: 164 ma @ 100 VCA |
Tension d'entrée | HV Models: 88 pour 300 VCC AC Models: 100 pour 240 VCA, 47 pour 63 hertz DC Models: ±48 VDC, 20 pour 72 VCC, -20 pour -72 VCC |
Fiabilité
Automatic Reboot Trigger | Built-in WDT |
Caractéristiques physiques
Logement | Métal |
Installation | 19-inch rack mounting |
Dimensions (avec des oreilles) | 480 X 45 X 198 millimètre (18.90 X 1.77 X 7.80 dans) |
Dimensions (sans oreilles) | 440 X 45 X 198 millimètre (17.32 X 1.77 X 7.80 dans) |
Lester | NPort 5650-16-HV-T: 3,820 g (8.42 kg) NPort 5650-8-HV-T: 3,720 g (8.20 kg) NPort 5610-16-48V: 3,260 g (7.19 kg) NPort 5610-8-48V: 3,160 g (6.97 kg) Norme 5630-16: 2,560 g (5.64 kg) NPort 5630-8/5650-16/5650-16-T: 2,510 g (5.53 kg) NPort 5650-16-S-SC: 2,500 g (5.51 kg) Norme 5610-16: 2,490 g (5.49 kg) NPort 5650-8-S-SC/5650-16-M-SC: 2,440 g (5.38 kg) Norme 5610-8: 2,290 g (5.05 kg) NPort 5650-8-M-SC: 2,380 g (5.25 kg) NPort 5650-8/5650-8-T: 2,310 g (5.09 kg) |
Interactive Interface | LCD panel display (standard temp. models only) Push buttons for configuration (standard temp. models only) |
Limites environnementales
Température de fonctionnement | Modèles standard: 0 à 60°C (32 à 140°F) Large température. Des modèles: -40 à 75 ° C (-40 à 167 ° F) High-voltage Wide Temp. Des modèles: -40 à 85°C (-40 à 185°F) |
Température de stockage (Emballage inclus) | Modèles standard: -20 à 70°C (-4 à 158 °F) Large température. Des modèles: -40 à 75 ° C (-40 à 167 ° F) High-voltage Wide Temp. Des modèles: -40 à 85°C (-40 à 185°F) |
Humidité relative ambiante | 5 pour 95% (sans condensation) |
Normes et certifications
CEM | DANS 55032/35 |
EMI | CISPR 32, FCC Partie 15B Classe A |
SME | Norme 5650-8/16 Des modèles: CEI 61000-4-2 ESD: Contact: 8 kv; Air: 15 kv CEI 61000-4-3 Rs: 80 MHz à 1 GHz: 10 V / m CEI 61000-4-4 Eft: Pouvoir: 4 kv; Signal: 2 kv CEI 61000-4-5 Surtension: Pouvoir: 2.5 kv; Signal: 1 kv CEI 61000-4-6 CS: 150 kHz to 80 MHz: 3 V / m; Signal: 3 V / m CEI 61000-4-8 CEI 61000-4-11 NPort 5650-8/16-HV Models: CEI 61000-4-2 ESD: Contact: 4 kv; Air: 8 kv CEI 61000-4-3 Rs: 80 MHz à 1 GHz: 3 V / m CEI 61000-4-4 Eft: Pouvoir: 4 kv; Signal: 2 kv CEI 61000-4-5 Surtension: Pouvoir: 2 kv CEI 61000-4-6 CS: 150 kHz to 80 MHz: 3 V / m; Signal: 3 V / m CEI 61000-4-8 |
Sécurité | UL 62368-1 |
Medical | DANS 55011: 2007+A2: 2007 Classe A (Group 1) conforme DANS 60601-1-2: 2007 conforme |
MTBF
Temps | Norme 5610-8: 903,009 HRS NPort 5610-8-48V: 892,692 HRS Norme 5630-8: 844,009 HRS NPort 5650-8-T: 776,469 HRS Norme 5650-8: 754,927 HRS NPort 5650-8-M-SC/8-S-SC: 738,291 HRS NPort 5650-8-HV-T: 716,168 HRS NPort 5610-16-48V: 693,529 HRS Norme 5610-16: 680,154 HRS Norme 5630-16: 618,263 HRS Norme 5650-16: 525,107 HRS NPort 5650-16-T: 533,046 HRS NPort 5650-16-M-SC/16-S-SC: 517,019 HRS NPort 5650-16-HV-T: 506,093 HRS |
Normes | HV Models: Telcordia (Clocher) Standard TR/SR All Other Models: MIL-HDBK-217F |
garantie
Période de garantie | 5 années |
Details | See www.moxa.com/warranty |
Contenu de package
Appareil | 1 x NPort 5600 Series device server |
Kit d'installation | 1 x rack-mounting kit |
Câble | 1 x power cord, suitable for your region (AC models) |
Documentation | 1 x Guide d'installation rapide 1 Card de garantie x |
Informations d'emballage

Expédition
Nos produits seront envoyés via FedEx,DHL,TNT,UPS,SME,Et ainsi de suite. Mais l'acheteur est responsable de
Dédouanement et tarif de paiement lorsque le produit est arrivé dans le pays de destination.
méthodes de livraison

2-4 jours ouvrables

2-4 jours ouvrables

2-4 jours ouvrables

5-7 jours ouvrables
Avis
Il n’y a pas encore d’avis.