سوبرمايكرو الترا سوبر سيرفر SYS-220U-TNR
Key Applications |
Virtualization |
HPC |
Cloud Computing |
High End Enterprise Server |
Software Defined Storage |
Application Tier Service Provider |
5G/Telco |
دلائل الميزات |
Dual Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable Processors |
Intel® C621A Chipset |
32 DIMM Slots; |
Up to 8TB DRAM; |
Up to 8TB Intel® Optane™ Persistent Memory (up to 12TB with DRAM); |
3200/2933/2666 ECC DDR4 LRDIMM;RDIMM; |
وحدات SKU للمنتج | |
SuperServer SYS-220U-TNR (Black Front & Silver Body) | |
اللوحة الأم | |
Super X12DPU-6 | |
المعالج | |
وحدة المعالجة المركزية | Dual Socket P+ (LGA-4189) |
3rd Gen Intel® Xeon® Scalable processors | |
Support CPU TDP 270W * | |
Cores | Up to 40C/80T; Up to 60MB Cache |
ملحوظة | *Certain CPUs with high TDP may be supported only under specific conditions. Please contact Supermicro Technical Support for additional information about specialized system optimization |
ذاكرة النظام | |
ذاكرة | Memory Capacity: 32 DIMM slots |
Up to 8TB: 32x 256 غيغابايت درام | |
Up to 12TB: 16x 512 GB PMem and 16x 256 غيغابايت درام | |
Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM;LRDIMM | |
Intel® Optane™ persistent memory 200 مسلسل | |
Memory Voltage | 1.2 الخامس |
Error Detection | إي سي سي |
On-Board Devices | |
SATA | SATA3 (6جيجابت في الثانية) via Intel® PCH 621A; غارة 0/1/5/10 يدعم |
NVMe | NVMe (16GT/s); غارة 0/1/5/10 يدعم |
NVMe (16GT/s); غارة 0/1/5/10 يدعم | |
Chipset | Intel® C621A |
Network Connectivity | 2x 10GbE BaseT with Intel® X710-AT2 (خياري) OR |
2x 10GbE BaseT and 2x 10GbE SFP+ with Intel® X710-TM4 (خياري) | |
No NIC option supported | |
IPMI | Support for Intelligent Platform Management Interface v.2.0 |
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support | |
Input / Output | |
لان | 1 RJ45 Dedicated BMC LAN port |
USB | 2 USB 3.0 ميناء(س) (2 rear) |
فيديو | 1 VGA port(س) |
منفذ تسلسلي | 1 COM Port(س) (1 rear) |
DOM | 2 SuperDOM (Disk on Module) ميناء |
System BIOS | |
BIOS Type | AMI 32MB SPI Flash EEPROM |
إدارة | |
برمجة | Supermicro Out of Band (OOB) رخصة (Included with Server) |
Redfish API | |
IPMI 2.0 | |
Intel® Node Manager | |
KVM with dedicated LAN | |
SUM | |
NMI | |
Watch Dog | |
SuperDoctor® 5 | |
Power Configurations | ACPI Power Management |
Power-on mode for AC power recovery | |
PC Health Monitoring | |
وحدة المعالجة المركزية | 7 +1 Phase-switching voltage regulator |
Monitors for CPU Cores, Chipset Voltages, ذاكرة | |
معجب | Fans with tachometer monitoring |
Pulse Width Modulated (PWM) fan connectors | |
Status monitor for speed control | |
درجة حرارة | Monitoring for CPU and chassis environment |
Thermal Control for fan connectors | |
الهيكل | |
شكل عامل | 2U Rackmount |
نموذج | CSE-219U3TS-R1K62P-T |
Dimensions and Weight | |
ارتفاع | 3.5″ (89مم) |
عرض | 17.2″ (437مم) |
عمق | 28.2″ (717.2مم) |
Package | 9.96″ (ح) x 24.6″ (دبليو) x 45.43″ (د) |
وزن | الوزن الصافي: 37 رطل (16.8 كلغ) |
الوزن الإجمالي: 63 رطل (28.6 كلغ) | |
اللون المتاح | Black Front & Silver Body |
اللوحة الامامية | |
Buttons | Power On/Off |
UID button | |
LEDs | نشاط الأقراص الصلبة |
LAN1 activity | |
LAN2 acticity | |
Power Fail | |
Power status | |
System information (overheat/UID) | |
فتحات التوسعة | |
PCI-Express (PCIe) | 1 PCIe 4.0 x16 FH, 10.5″L slot(س) |
5 PCIe 4.0 x8 FH, 10.5″L slot(س) | |
1 PCIe 4.0 x8 Internal LP slot(س) | |
1 PCIe 4.0 x16 LP slot(س) | |
ملحوظة | Optional RSC-W2-66G4 enables PCIe x16 in slots 5, 7. Slots 6,8 will be disabled. |
حملة الخلجان / تخزين | |
Hot-swap | 24× 2.5″ hot-swap NVMe/SATA/SAS drive bays (22× 2.5″ NVMe hybrid) (SAS/NVMe support requires additional parts. Please see the Optional Parts list.) |
System Cooling | |
المشجعين | 4x 8cm heavy duty fans with optimal fan speed control |
كفن الهواء | 2 كفن الهواء(س) |
مزود الطاقة | |
1U 1600W Redundant Titanium AC Power Supply with PMbus 73.5x203x40mm | |
Dimension | 73.5 x 40 x 203 مم |
(العرض × الارتفاع × الطول) | |
AC Input | 1000دبليو: 100-127بطالة / 50-60هرتز |
1600دبليو: 200-240بطالة / 50-60هرتز | |
+12الخامس | الأعلى: 83أ / دقيقة: 0أ (100Vac-127Vac) |
الأعلى: 133أ / دقيقة: 0أ (200Vac-240Vac) | |
12V SB | الأعلى: 2.1أ / دقيقة: 0أ |
نوع الإخراج | Gold Finger Connector |
شهادة | Titanium Level |
[ Test Report ] | |
بيئة التشغيل | |
Environmental Spec. | درجة حرارة التشغيل: |
10°C ~ 35°C (50°F ~ 95°F) | |
Non-operating Temperature: | |
-40°C to 60°C (-40°F to 140°F) | |
Operating Relative Humidity: | |
8% ل 90% (غير التكثيف) | |
Non-operating Relative Humidity: | |
5% ل 95% (غير التكثيف) |
تخصيص
Standard Parts (Parts Included) | |||
رقم القطعة | الكمية | وصف | |
اللوحة الأم / الهيكل | MBD-X12DPU-6 | 1 | Super X12DPU-6 Motherboard |
CSE-219U3TS-R1K62P-T | 1 | 2هيكل يو | |
لوحة الكترونية معززة | BPN-NVME4-216N-S24 | 1 | 2U 24-slot all-hybrid direct-attached backplane, support 24x 2.5 |
كابل | CBL-CDAT-0674 | 2 | 4 Pin to 4 Pin I2C Cable, 30سم, 26الفريق العامل المخصص, 4 Wires, Pinout 1-1 |
CBL-PWEX-0924 | 1 | 2×4,P3.0 to 2×4,P4.2,YL/RED,9.5أ,24سم,16الفريق العامل المخصص,بنفايات | |
CBL-PWEX-0925 | 2 | 2×4,P3.0 to 2×4,P4.2,YL/RED,9.5أ,55سم,16الفريق العامل المخصص,بنفايات | |
CBL-SAST-1250F-100 | 2 | Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,50سم,100 | |
CBL-SAST-1270F-100 | 1 | Slimline x4 (STR) to Slimline x4 (STR),FFC,INT,70سم,100 | |
مصرف ليبيا المركزي-0088ل | 4 | 10.5″ 4PIN FAN POWER CORD FOR 743X-645,PBF | |
مصرف ليبيا المركزي-0160ل | 2 | سلك الطاقة الأمريكي 16AWG, بي بي مجاني | |
Riser Card | RSC-W2-8888G4 | 1 | 2U LHS WIO Riser card with four PCIe 4.0 x8 slots,HF,بنفايات |
RSC-WR-6 | 1 | 1U RHS WIO Riser card with one PCIe 4.0 x16 slot,HF,بنفايات | |
برمجة | SFT-OOB-LIC | 1 | License key for enabling OOB BIOS management |
Heatsink / Retention | SNK-P0078P | 2 | 2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*مزود الطاقة | PWS-1K62A-1R | 2 | AC-DC 1600W, Titanium Level, وفرة, 1يو, DC Output: +12V and +12Vs, 203 x 73.5 x 40 مم, AC Input: 90 – 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH |
*علبة القيادة(س) | MCP-220-00047-0B | 24 | علبة HDD مقاس 2.5 بوصة باللون الأسود من الجيل الثالث قابلة للتبديل السريع |
*Rail Set | MCP-290-00057-0N | 1 | Rail set, quick/quick, default for 4U 17.2″ دبليو |
MCP-290-00060-0N | 1 | Threaded rail adapter default for round hole rack | |
MCP-290-00115-0N | 1 | السكك الحديدية الداخلية, quick-release type | |
MCP-290-00117-0N | 1 | السكك الحديدية الخارجية, quick-release type | |
*كفن الهواء | MCP-310-81905-0B | 1 | Plastic air shroud for SC819U, 119يو, 829يو, 219يو (PWS),RoHS/REACH |
*معجب | معجب-0209L4 OR | 4 | 80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above |
معجب-0206L4 | 80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers | ||
Notes: | |||
Parts with * are inside the chassis | |||
Excessive parts might not be shipped, including but not limited to excessive drive trays, المشجعين, riser brackets, air shrouds, IO shields, cables…..إلخ. | |||
Optional Parts List | |||
رقم القطعة | الكمية | وصف | |
2 Rear 2.5″ Hot-swap SATA Drive Bays (Complete System Only) | MCP-240-82922-0N-OEM • | 1 | Rear 2x 2.5″ HDDs riser bracket kit for SC829U/219U, tool-less |
2U Cable Management Arm | MCP-290-00128-0N & | 1 | 2U Supermicro Cable Management Arm 2nd Gen (Compatible for racks that are 42″ in depth) |
MCP-290-00127-0N | |||
2U Front Bezel | MCP-210-82601-0B • | 1 | Black Front Bezel Suitable for 829U and 219U chassis with standard thumbscrew handle. |
Add-on card for M.2 support | AOC-SLG3-2H8M2-O | – | 2x Hybrid NVMe/SATA M.2 RAID Carrier, Standard LP,بنفايات |
CacheVaults | BTR-CVPM05 + BKT-BBU-BRACKET-05 | – | CacheVault for Broadcom 3908/3916 with Supercap |
BTR-CV3108-U1 | – | CacheVault for Broadcom 3108 with Supercap mounting for 2U Ultra | |
علبة القيادة | MCP-220-00167-0B • | 1 ~ 22 | 2.5 drive tray, Orange tab (for hotswap NVMe drive) |
Global Services & يدعم | OSNBD3/2/1 | – | 3/2/1-year onsite NBD service |
OS4HR3/2/1 | – | 3/2/1-year onsite 24x7x4 service | |
Intel® VROC RAID Key Options | AOC-VROCINTMOD | 1 | Intel VROC, غارة 0, 1, 5, 10 (Intel SSD Only) |
AOC-VROCPREMOD • | 1 | Intel VROC Premium, غارة 0, 1, 5, 10 | |
AOC-VROCSTNMOD | 1 | Intel VROC Standard, غارة 0, 1, 10 | |
Network Card(س) | AOC Compatibility Matrix | – | Standard Networking AOC Matrix |
NVMe Support Kit | CBL-KIT-220U-TNR-22N + 3 AOC-SLG4-4E4T-O | 1 | 22 NVMe Support Kit for X12 Ultra 220U-TNR without NIC UIO |
CBL-KIT-220U-TNR-22 + 2 AOC-SLG4-2E4T-O + 2 AOC-SLG4-4E4T-O | 1 | 22 NVMe Support Kit for X12 Ultra 220U-TNR with NIC UIO | |
CBL-KIT-220U-TNR-8 | 1 | 8 NVMe Support Kit for X12 Ultra SYS-220U-TNR | |
Optional Storage Controller Card + كابل(س) | AOC-S3108L-H8iR-16DD + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; غارة 0, 1, 5, 6, 10, 50, 60 |
AOC-S3908L-H8iR-16DD-O + 1x CBL-SAST-1276F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-4; غارة 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3008L-L8i + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; RAID 0,1,1E | |
AOC-S3916L-H16iR-32DD-O + 1x CBL-SAST-1264F-100, 1x CBL-SAST-1276F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 16 internal ports (12Gb/s) Gen-4; غارة 0, 1, 5, 6, 10, 50, 60 | |
AOC-S3008L-L8E+-O + 1x CBL-SAST-1260-100 or + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA + I2C | |
AOC-S3008L-L8E + 1x CBL-SAST-1260-100 or AOC-S3008L-L8E + 2x CBL-SAST-1285-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-3; HBA | |
AOC-S3808L-L8iT-O + 1x CBL-SAST-1264F-100 or + 1x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 8 internal ports (12Gb/s) Gen-4; HBA | |
AOC-S3816L-L16iT-O + 2x CBL-SAST-1264F-100 or + 2x CBL-SAST-1264F-100 (For system has 22 NVMe Support Kit with NIC UIO) | – | Standard LP, 16 internal ports (12Gb/s) Gen-4; HBA | |
مزود الطاقة | PWS-1K30D-1R • | 2 | 1U 1300W, وفرة, DC Input: -48Vdc |
PWS-2K08A-1R • | 2 | 1U 2000W, Titanium Level, وفرة, AC Input: 90-264VAC/47-63Hz, and wide DC input 180Vdc~300Vdc | |
Riser Card | RSC-W2-688G4 | 1 | 2U LHS WIO Riser card with one PCIe 4.0 x16 and two PCIe 4.0 x8 |
RSC-W2-66G4 | 1 | 2U LHS WIO Riser card with two PCIe 4.0 x16 slots,HF,بنفايات | |
برمجة | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
Trusted Platform Module Options | AOM-TPM-9670V-S-FIPS-P | 1 | AOM-TPM-9670V-S-FIPS TPM 2.0 support TAA and FIPS,بنفايات |
AOM-TPM-9671V-O | 1 | SPI Capable Vertical TPM 1.2 Module | |
AOM-TPM-9670V-O | 1 | SPI TPM 2.0 using SLB9670 | |
Ultra Riser Card Options + النافذة الخلفية | AOC-2UR668G4-O | 1 | 2U Ultra Riser with 2x PCIe 4.0 x16 and 1x PCIe 4.0 x8 (داخلي, in x16),بنفايات |
AOC-2UR68G4-I2XT-O + MCP-240-82909-0N | 1 | 2U Ultra Riser with 2-port 10G RJ45, Intel Carlsville X710-AT2, 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0×8 (داخلي, in x16),بنفايات | |
AOC-2UR68G4-I4XTS-O + MCP-240-82930-0N | 1 | 2U Ultra Riser with 2-port 10G RJ45 & 2-port 10G SFP+, Intel Carlsville X710-TM4, مع 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0×8 (داخلي, in x16),بنفايات | |
AOC-2UR68G4-M2TS + MCP-240-82914-0N | 1 | 2U Ultra Riser 2-port 25GbE SFP28, Mellanox CX-6 LX, 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0×8 (داخلي, in x16),بنفايات |
جمع معلومات
Ultra SuperServer SYS-220U-TNR is sealed in Brocade original box. We will also pack SuperServer SYS-220U-TNR the second box before shipping.
شحنة
سيتم إرسال منتجاتنا عبر FedEx,DHL,مادة تي إن تي,يو بي إس,EMS,وهلم جرا. ولكن المشتري هو المسؤول عن
التخليص الجمركي ودفع التعريفة الجمركية عند وصول المنتج إلى بلد المقصد.
المراجعات